AMS PUMP MF 0340 FP 230VAC - DIGITAL CONSTANT/PROPORTIONAL DOSING PUMP 40 L/H - 3 BAR - EMEC

AMS PUMP MF 0340 FP 230VAC - DIGITAL CONSTANT/PROPORTIONAL DOSING PUMP 40 L/H - 3 BAR - EMECAMS PUMP MF 0340 FP 230VAC - DIGITAL CONSTANT/PROPORTIONAL DOSING PUMP 40 L/H - 3 BAR - EMECAMS PUMP MF 0340 FP 230VAC - DIGITAL CONSTANT/PROPORTIONAL DOSING PUMP 40 L/H - 3 BAR - EMECAMS PUMP MF 0340 FP 230VAC - DIGITAL CONSTANT/PROPORTIONAL DOSING PUMP 40 L/H - 3 BAR - EMECAMS PUMP MF 0340 FP 230VAC - DIGITAL CONSTANT/PROPORTIONAL DOSING PUMP 40 L/H - 3 BAR - EMECAMS PUMP MF 0340 FP 230VAC - DIGITAL CONSTANT/PROPORTIONAL DOSING PUMP 40 L/H - 3 BAR - EMECAMS PUMP MF 0340 FP 230VAC - DIGITAL CONSTANT/PROPORTIONAL DOSING PUMP 40 L/H - 3 BAR - EMECAMS PUMP MF 0340 FP 230VAC - DIGITAL CONSTANT/PROPORTIONAL DOSING PUMP 40 L/H - 3 BAR - EMECAMS PUMP MF 0340 FP 230VAC - DIGITAL CONSTANT/PROPORTIONAL DOSING PUMP 40 L/H - 3 BAR - EMEC
Price:

847,67 Iva Inclusa

Item code: 05EC-AMSMF0340
Brand: EMEC
Download e Allegati:
Availability: Available Consegna entro 10/15 Giorni
Quantity:

Users feedback

Description

AMS PUMP MF 0340 FP 230VAC - DIGITAL CONSTANT/PROPORTIONAL DOSING PUMP
Flow rate: 40 L/H - 3 BAR back pressure

AMS MF is the multifunction series because it allows you to set different working modes: Constant, Divide, Multiply, ppm, perc, mlq, batch, volt, mA.
Additionally, you can:
- set automatic re-priming, with a flow sensor installed (sefl
- enable lost shots recovery system (sefl menu)
- set a maintenance dosage in case of plant shutdown (ppm menu - upkeep setting).

The pump is equipped with:
- STAND-BY input
- SEFL input (flow sensor
- LEVEL input (level control)
- ALARM contact output.

The dosage of the pump is determined by the number of pulses and the capacity per single injection.
The adjustment of the single injection is linear only on values between 30% and 100%.
The operating and control parameters are displayed on an LCD display and managed via a keyboard

Characteristics
- Horizontal mounting, with display
- Microprocessor
- Mechanical adjustment of the volume of the single injection
- Pump body with manual bleed (AMS)
- Box: polypropylene
- Ambient temperature: 10 ÷ 45°C (55 ÷ 113°F)
- Additive temperature: 0 ÷ 50°C (32 ÷ 122°F)
- Transport and storage temperature: 10 ÷ 50°C (55 ÷ 122°F)
- Altitude: 2000 m asl
- Installation class: II
- Pollution level: 2
- Audible Noise: 57.4db(A)
- Protection: IP 65 (NEMA4X) - Operating RH %: 85% with t =40 °C; 70% at 45°C

Included in the package:
- PVDF injection valve calibrated at 0.3 bar
- PVDF level probe
- bottom filter in PVDF
- 2 meters of suction hose (8x12 flexible PVC)
- 2 meters of delivery pipe (PVDF 8x10)
- 2 meters of air discharge hose (PVC 4x6)
- 1 operating manual

Features

Type dosage:Costante/Proporzionale
Level control:Yes
Pressure (bar):3
Flow (L/h):40
Type pump body:S
Pulse min.:1 imp/ora
Pulse max:120 imp/min
Tube aspiration:PVC 8 x 12
Tube injection:PVDF 8 x 10
Flow max L/h:40
Modalità di programmazione:- CONSTANT: la pompa dosa con frequenza costante
- DIVIDE: li impulsi forniti da un contatore connesso alla pompa, sono divisi per il valore
impostato durante la fase di programmazione e ne determinano la frequenza di dosaggio
- MULTIPLY: gli impulsi forniti da un contatore connesso alla pompa, sono moltiplicati per il
valore impostato durante la fasedi programmazione e ne determinano la frequenza di dosaggio
PPM: gli impulsi forniti da un contatore connesso alla pompa determinano il dosaggio in
funzione del valore di PPM impostato. La concentrazione del prodotto dosato e la quantità
per singolo colpo deve essere impostato durante la fase di programmazione
- BATCH: l’impulso fornito da un contatto esterno avvia il dosaggio della quantità di prodotto
impostato durante la fase di programmazione
- VOLT: la tensione fornita alla pompa (tramite il segnale in ingresso) determina il dosaggio
proporzionale in funzione dei due valori minimo e massimo nei quali sono stati impostati i
colpi minuto durante la fase di programmazione
- mA: grazia corrente fornita alla pompa (tramite il segnale in ingresso) determina il dosaggio
proporzionale in funzione dei due valori minimo e massimo nei quali sono stati impostati
i colpi minuto durante la fase di programmazione

Feedback